SMS Alert with remote Programming

The Alarm PCB Monitor 8 inputs. If any of the input change state, it will send SMS up to 8 person.

It can be programmed, list the 8 programmed handphone number as well as 16 messages via SMS.

 

When Power Up, LCD display "SMS Alarm " If all inputs are opened, After a while display "Monitoring".

If there is alarm, After sending SMS, it display " . . . Alarm . . . "

 

Programming

Assume you want to program the 1st handphone number as 11111111 and sending message handphone number

is 96580564.

Sending message : *save_000:_s11111111 #

LCD display : Display +6596580564

s1111111

Reply message : Reply: Saved 000

Handphone number 11111111 will be store in memory as 1st number.

To ignore the handphone number. Type *save_000:_a111 # send

Or any letters other than s.

Example : Below table show only One handphone Num is programmed, that is Num 8, the rest are ignored but must programmed as well.

Note : It is advisable to waited for the reply message before program the next number/message.

 

Example

 

Num 1

*save_000:_a11111111 #

s > SMS; ( Max 32 characters )

Num 2

*save_001:_a22222222 #

s > SMS ; ( Max 32 characters )

Num 3

*save_002:_a33333333 #

s > SMS; ( Max 32 characters )

Num 4

*save_003:_a44444444 #

s > SMS; ( Max 32 characters )

Num 5

*save_004:_a55555555 #

s > SMS ( Max 32 characters )

Num 6

*save_005:_a66666666 #

s > SMS; ( Max 32 characters )

Num 7

*save_006:_a77777777 #

s > SMS; ( Max 32 characters )

Num 8

*save_007:_s96580564 #

s > SMS ( Max 32 characters )

Message 1 fail

*save_008:_Alarm 111 fail #

Input 1 contact closed message ( Max 30)

Message 1 ok

*save_009:_Alarm 111 ok #

Input 1 contact opened message ( Max 30)

Message 2 fail

*save_010:_Alarm 222 fail #

Input 2 contact closed message ( Max 30)

Message 2 ok

*save_011:_Alarm 222 ok #

Input 2 contact open message ( Max 30)

Message 3 fail

*save_012:_Alarm 333 fail #

Input 3 contact closed message ( Max 30)

Message 3 ok

*save_013:_Alarm 333 ok #

Input 3 contact opened message ( Max 30)

Message 4 fail

*save_014:_Alarm 444 fail #

Input 4 contact closed message ( Max 30)

Message 4 ok

*save_015:_Alarm 444 ok #

Input 4 contact opened message ( Max 30)

Message 5 fail

*save_016:_Alarm 555 fail #

Input 5 contact closed message ( Max 30)

Message 5 ok

*save_017:_Alarm 555 ok #

Input 5 contact opened message ( Max 30)

Message 6 fail

*save_018:_Alarm 666 fail #

Input 6 contact closed message ( Max 30)

Message 6 ok

*save_019:_Alarm 666 ok #

Input 6 contact opened message ( Max 30)

Message 7 fail

*save_020:_Alarm 777 fail #

Input 7 contact closed message ( Max 30)

Message 7 ok

*save_021:_Alarm 777 ok #

Input 7 contact opened message ( Max 30)

Message 8 fail

*save_022:_Alarm 888 fail #

Input 8 contact closed message ( Max 30)

Message 8 ok

*save_023:_Alarm 888 ok #

Input 8 contact opened message ( Max 30)

Spare 1

 

 

Spare 2

 

 

Spare 3

 

 

Spare 4

*save_027:_relay_1_on #

 

Spare 5

*save_028:_relay_1_off #

 

Spare 6

*save_029:_relay_2_on #

 

Spare 7

*save_030:_relay_2_off #

 

 

list_hp#

List all the handphone number

 

list_mess#

List all the message

 

To list down all the 8 handphone numbers

Sending message : list_hp#

LCD display : List 8 phone number

Reply message :

1.a11111111

2.a22222222

3.a33333333

4.a44444444

5.a55555555

6.a66666666

7.a77777777

8.s96580564

 

To list down all the 16 messages

Sending message : list_mess#

LCD display : List 16 messages

Reply message :

1. Alarm 111 fail

2. Alarm 111 ok

3. Alarm 222 fail

4. Alarm 222 ok

 

5. Alarm 333 fail

6. Alarm 333 ok

7. Alarm 444 fail

8. Alarm 444 ok

 

9. Alarm 555 fail

10.Alarm 555 ok

11.Alarm 666 fail

12.Alarm 666 ok

 

13. Alarm 777 fail

14.Alarm 777 ok

15.Alarm 888 fail

16.Alarm 888 ok

 

Dimension 95mm x 65mm