SMS Alert with remote Programming
The Alarm PCB Monitor 8 inputs. If any
of the input change state, it will send SMS up to 8 person.
It can be programmed, list the 8 programmed handphone number as
well as 16 messages via SMS.
When Power Up, LCD display "SMS Alarm " If all inputs
are opened, After a while display "Monitoring".
If there is alarm, After sending SMS, it display " . . .
Alarm . . . "
Programming
Assume you want to program the 1st handphone
number as 11111111 and sending message handphone number
is 96580564.
Sending message :
*save_000:_s11111111 #
LCD display :
Display +6596580564
s1111111
Reply
message : Reply: Saved 000
Handphone
number 11111111 will be store in memory as 1st number.
To ignore the
handphone number. Type *save_000:_a111 # send
Or any
letters other than s.
Example :
Below table show only One handphone Num is programmed, that is Num 8, the rest
are ignored but must programmed as well.
Note : It is
advisable to waited for the reply message before program the next
number/message.
|
Example |
|
Num 1 |
*save_000:_a11111111 # |
s –> SMS; ( Max 32 characters ) |
Num 2 |
*save_001:_a22222222 # |
s –> SMS ; ( Max 32 characters ) |
Num 3 |
*save_002:_a33333333 # |
s –> SMS; ( Max 32 characters ) |
Num 4 |
*save_003:_a44444444 # |
s –> SMS; ( Max 32 characters ) |
Num 5 |
*save_004:_a55555555 # |
s –> SMS ( Max 32 characters ) |
Num 6 |
*save_005:_a66666666 # |
s –> SMS; ( Max 32 characters ) |
Num 7 |
*save_006:_a77777777 # |
s –> SMS; ( Max 32 characters ) |
Num 8 |
*save_007:_s96580564 # |
s –> SMS ( Max 32 characters ) |
Message 1 fail |
*save_008:_Alarm 111 fail # |
Input 1 contact closed message ( Max
30) |
Message 1 ok |
*save_009:_Alarm 111 ok # |
Input 1 contact opened message ( Max 30) |
Message
2 fail |
*save_010:_Alarm 222 fail # |
Input 2 contact closed message ( Max 30) |
Message
2 ok |
*save_011:_Alarm 222 ok # |
Input 2 contact open message ( Max 30) |
Message 3 fail |
*save_012:_Alarm 333 fail # |
Input 3 contact closed message ( Max 30) |
Message 3 ok |
*save_013:_Alarm 333 ok # |
Input 3 contact opened message ( Max 30) |
Message
4 fail |
*save_014:_Alarm 444 fail # |
Input 4 contact closed message ( Max 30) |
Message
4 ok |
*save_015:_Alarm 444 ok # |
Input 4 contact opened message ( Max 30) |
Message 5 fail |
*save_016:_Alarm 555 fail # |
Input 5 contact closed message ( Max 30) |
Message 5 ok |
*save_017:_Alarm 555 ok # |
Input 5 contact opened message ( Max 30) |
Message
6 fail |
*save_018:_Alarm 666 fail # |
Input 6 contact closed message ( Max 30) |
Message
6 ok |
*save_019:_Alarm 666 ok # |
Input 6 contact opened message ( Max 30) |
Message 7 fail |
*save_020:_Alarm 777 fail # |
Input 7 contact closed message ( Max 30) |
Message 7 ok |
*save_021:_Alarm 777 ok # |
Input 7 contact opened message ( Max 30) |
Message
8 fail |
*save_022:_Alarm 888 fail # |
Input 8 contact closed message ( Max 30) |
Message
8 ok |
*save_023:_Alarm 888 ok # |
Input 8 contact opened message ( Max 30) |
Spare 1 |
|
|
Spare 2 |
|
|
Spare 3 |
|
|
Spare 4 |
*save_027:_relay_1_on # |
|
Spare 5 |
*save_028:_relay_1_off # |
|
Spare 6 |
*save_029:_relay_2_on # |
|
Spare 7 |
*save_030:_relay_2_off # |
|
|
list_hp# |
List all the handphone number |
|
list_mess# |
List all the message |
To list down all the 8 handphone
numbers
Sending message :
list_hp#
LCD display :
List 8 phone number
Reply
message :
1.a11111111
2.a22222222
3.a33333333
4.a44444444
5.a55555555
6.a66666666
7.a77777777
8.s96580564
To list down all the 16 messages
Sending message :
list_mess#
LCD display :
List 16 messages
Reply
message :
1. Alarm 111 fail
2. Alarm 111 ok
3. Alarm 222 fail
4. Alarm 222 ok
5. Alarm 333 fail
6. Alarm 333 ok
7. Alarm 444 fail
8. Alarm 444 ok
9. Alarm 555 fail
10.Alarm 555 ok
11.Alarm 666 fail
12.Alarm 666 ok
13. Alarm 777 fail
14.Alarm 777 ok
15.Alarm 888 fail
16.Alarm 888 ok
Dimension 95mm x 65mm
Operated on DC 12V